Claymax 200R

Claymax®200R is a non-reinforced GCL with two lightweight nonwoven geotextiles encapsulating a layer of Volclay® sodium bentonite. Ideally suited for mild slopes, Claymax 200R maximizes both performance and value in one ingeniously straightforward product. A completely self-seaming GCL, there's simply no better GCL than Claymax 200R for lining the flat areas of a landfill.

Propriétés
Material property Test method Test frequency (m²) Required values
Bentonite Swell Index1 ASTM D 5890 1 per 50 tonnes 24 ml/2g min
Bentonite Fluid Loss1 ASTM D 5891 1 per 50 tonnes 18 ml max
Bentonite Mass/Area2 ASTM D 5993 4 000 m² 3,6 kg/m² min
GCL Peel Strength3 ASTM D 6768 20 000 m² 70 N/cm MARV
GCL Peel Strength3 ASTM D 6496 N/D N/D
GCL Index Flux4 ASTM D 5887 Weekly 1 x 10-8 m³/m²/sec max
GCL Hydraulic Conductivity4 ASTM D 5887 Weekly 5 x 10-9 cm/sec max
GCL Hydrated InternalShear Strength5 ASTM D 5321
ASTM D 6243
Periodic 4,8 kPa typique
Panel specifications
Products Dimensions width x length Area Effective area
Claymax 200R 4,6 m x 45,7 m
(15 ft x 150 ft)
209 m²
(2 250 ft²)
190 m²
(2 040 ft²)
Caractéristiques des rouleaux
Products Dimensions length x dia. Nominal weight Rolls/Truckload
Claymax 200R 4,9 m x 510 mm
(16 ft x 20 in)
1 250 kg
(2 750 lbs)
14 rolls
per truckload


Notes
  1. Bentonite property tests performed at a bentonite processing facility before shipment to CETCO's GCL production facilities.
  2. Bentonite mass/area reported at 0 percent moisture content.
  3. All tensile strength testing is performed in the machine direction using ASTM D 6768. All peel strength testing is performed using ASTM D 6496. Upon request, tensile and peel results can be reported per modified ASTM D 4632 using 4 inch grips.
  4. Index flux and permeability testing with deaired distilled/deionized water at 80 psi (551kPa) cell pressure, 77 psi (531 kPa) headwater pressure and 75 psi (517 kPa) tailwater pressure. Reported value is equivalent to 925 gal/acre/day. This flux value is equivalent to a permeability of 5x10-9 cm/sec for typical GCL thickness. Actual flux values vary with field condition pressures. The last 20 weekly values prior the end of the production date of the supplied GCL may be provided.
  5. Peak values measured at 200 psf (10 kPa) normal stress for a specimen hydrated for 48 hours. Site-specific materials, GCL products, and test conditions must be used to verify internal and interface strength of the proposed design.